EETP OÜ
Expertise in Boiler
Expertise in Cement and Lime
Expertise in DRI
Expertise in Waste incineration
Expertise in Steel
Expertise in Petrochem
Expertise in Aluminium
Expertise in Iron
Expertise in Foundry
Expertise in Ferro-Alloys

Calderys products

Refractory casting mass

CALDE™ CAST F 53

Usage: gas and oil heating furnaces, casting of refractory masonry, thermal expansion seams

Thickness: minimal of 70 mm, maximal 350 mm

Operating temperature: up to 1500 °C

 

CALDE™ CAST LX 58

Usage: gas and oil heating furnaces, casting of refractory masonry, thermal expansion seams.

Thickness: minimal of 70 mm, maximal 350 mm.

Operating temperature: up to 1650 °C

 

CALDE™ CAST 50 A

Usage: furnaces with wood or peat heating (alkaline ash is produced), casting of refractory masonry, thermal expansion seams.

Thickness: minimal of 70 mm, maximal 350 mm.

Operating temperature: up to 1500 °C.

 

CALDE™ CAST HYMOR 2800

Usage: furnaces with gas, oil, wood or peat heating, casting of refractory masonry, is more durable than CALDE™ CAST F 53 and CALDE™ CAST 50 A, otherwise more or less the same, thermal expansion seams.

Thickness: minimal of 70 mm, maximal 350 mm.

Operating temperature: up to 1500 °C.

 

REFRACTORY STAMP MASS

CALDE™ PLAST SUPERAL X AB

Usage: refractory masonry stamp mass, thermal expansion seams.

Thickness: minimal of 70 mm, maximal 350 mm.

Operating temperature: up to 1650 °C.

 

CALDE™ PLAST REDD RAM

Usage: refractory masonry stamp mass, chemically and physically very resistant, used under difficult conditions (for example humid)- edges of the grids in hearths, in case of wood and peat, places of entrance for the fuel in the hearth, thermal expansion seams.

Thickness: minimal of 70 mm, maximal 350 mm.

Operating temperature: up to 1650 °C.

 

CALDE™ PLAST SUPERAL AB

Usage: refractory masonry stamp mass, thermal expansion seams.

Thickness: minimal of 70 mm, maximal 350 mm.

Operating temperature: up to 1600 °C.

 

Mortar for bricklaying

CALDE™ TROWEL HF 36 U

Wet mortar with operating temperature of 1600 °C, laying of firebricks wall, consumption 250-300 grams per brick (230x114x64 mm).

 

CALDE™ TROWEL PB 78

Dry cement with operating temperature of 1800 °C, laying of firebricks wall, consumption of materials 180 kg/m3 for laying firebricks (230x114x64 mm).

 

CORRECTION MIXTURE

CALDE™ STIX 15

Usage: refractory masonry correction mass- for filling cracks, fissures and holes, the material where the holes are, is irrelevant, coefficient of thermal expansion is 0- it does not expand nor shrink or fall out of the hole.

Thickness: for filling holes of different sizes, apply layer of 5 cm, let it dry and apply new layer.

Operating temperature: up to 1550 °C.

 

INSULATION MATERIAL

CALDE™ CAST XL 106 C/G

Usage: insulation material: when furnace wall of 2-3 layers is made, it is installed as outer layer (furthest from the fire) because it conducts heat worst. No need for thermal expansion seams.

Thickness: minimal of 0 mm, maximal 350 mm.

Operating temperature: up to 1060 °C.

 

refractory bricks, stones:

Firebricks, bricks product range is very wide pursuant to working environment and temperature.

If interested, please send us a price request with information on where you want to use the stones and what are the temperatures, so that we can offer a suitable solution for you.

 

Intermediate concretes:

Plicast LWI 22 (1280 °C)

Plicast Verilite (950 °C)

 

CALDE™ CAST MW STRONG LITE (1360 °C)

In case of 3-layer masonry the medium layer of intermediate concrete is created between refractory and insulation layer (to be cheaper and better insulation material, 3-layer brickwork is stronger than 2-layered). Intermediate concretes may be used for insulation.

 

insulation material for turbines

Limpet BD-6

Extremely efficient sound- and insulation material, elaborated in the 1970s to replace asbestos.

 

REFRACTORY CONCRETE COMPONENTS

It is possible to order refractory concrete ready-to-use components according to customer drawings.

 

Anchors

Y- ANCHORS of stainless material AVESTA 253 MA

Y- anchors can be obtained with the following measures: thickness 3-5 mm, width and length according to the client desire.

Anchors should be installed 16 pieces per 1 m2, end of the anchor must stay 25-35mm inside the masonry. Outer ends of the anchor must be covered with paint or bitumen..

 

More info can be found on: www.calderys.com